Nee. | Modell | Input Muecht | Max. Loftvolumen (m3/min) | Air Päif Verbindung | Kältemëttel Modell |
1 | TRV-01 | 0,28 | 1.2 | 3/4'' | R134a |
2 | TRV-02 | 0,34 | 2.4 | 3/4'' | R134a |
3 | TRV-03 Eng | 0,37 | 3.6 | 1'' | R134a |
4 | TRV-06 Eng | 0,99 | 6.5 | 1-1/2'' | R410A |
5 | TRV-08 | 1.5 | 8.5 | 2'' | R410A |
6 | TRV-10 Eng | 1.6 | 10.5 | 2'' | R410A |
7 | TRV-12 Eng | 1,97 | 13 | 2'' | R410A |
8 | TRV-15 Eng | 3.8 | 17 | 2'' | R407C |
9 | TRV-20 | 4 | 23 | 2-1/2'' | R407C |
10 | TRV-25 Eng | 4.9 | 27 | DN80 | R407C |
11 | TRV-30 Eng | 5.8 | 33 | DN80 | R407C |
12 | TRV-40 Eng | 6.3 | 42 | DN100 | R407C |
13 | TRV-50 Eng | 9.7 | 55 | DN100 | R407C |
14 | TRV-60 Eng | 11.3 | 65 | DN125 | R407C |
15 | TRV-80 Eng | 13.6 | 85 | DN125 | R407C |
16 | TRV-100 Eng | 18.6 | 110 | DN150 | R407C |
17 | TRV-120 Eng | 22.7 | 130 | DN150 | R407C |
18 | TRV-150 Eng | 27.6 | 165 | DN150 | R407C |
1. Ambient Temperatur: -10 ℃, Max. 45 ℃ | |||||
2. Entrée Temperatur: 15 ℃, Max. 65 ℃ | |||||
3. Aarbechtsdrock: 0.7MPa, Max.1.6Mpa | |||||
4. Drock Taupunkt: 2 ℃ ~ 8 ℃ (Loft Taupunkt: -23 ℃ ~ -17 ℃) | |||||
5. Kee Sonneliicht, kee Reen, gutt Belëftung, installéiert op engem horizontalen haarde Fundament, kee offensichtleche Stëbs a fléien Kazen |
1.Energiespueren:
D'Applikatioun vun DC Frequenz Konversioun Technologie erlaabt der Loft Dryer déi richteg automatesch Conditioun Fähegkeet ze realiséieren, de Minimum Betribssystemer Muecht ass nëmmen ongeféier 20% vun der Muecht Frequenz Loft Dryer, an der Stroum Rechnung an engem Joer gerett kann no bei oder recuperéieren der Käschte vun der Loft Dryer.
2.Effektiv:
De Segen vun dräi-an-eent Aluminiumplack Ersatz, kombinéiert mat DC Frequenz Konversioun Technologie, mécht d'Performance vun der Loft Dryer verbessert duerch Sprangen a Grenzen, an et ass einfach den Taupunkt ze kontrolléieren.
3. Intelligent:
Laut der Ännerung vun den Aarbechtsbedingunge kann d'Frequenz vum Kompressor automatesch ugepasst ginn, an de Betribsstatus kann automatesch beurteelt ginn. op ee Bléck.
4.Ëmweltschutz:
Als Äntwert op den internationale Montreal Protokoll. dëser Serie vun Modeller all benotzen R134a an R410A ëmweltfrëndlech refrigerants, déi null Schued un der Atmosphär hunn an d'Besoine vun der internationaler Maart treffen.
5. Stabilitéit:
D'automatesch Upassungsfunktioun vun der Frequenzkonversiounstechnologie mécht d'Betribstemperaturberäich vum kale Trockner méi breet. Ënnert dem extremen héijen Temperaturbedingung mécht d'Vollgeschwindegkeet Ausgang datt d'Taupunkttemperatur séier um bewäertte Wäert stabiliséiert, an an der extremer niddereger Temperatur Klimaanlag am Wanter, passt d'Frequenzausgang un fir Äisblockéierung am kale Trockner ze vermeiden a garantéiert eng stabile Taupunkt.
1.Using R134a ëmweltfrëndlech Kältemëttel, gréng Energie spueren;
2.De Segen vun dräi-an-eent Aluminiumplack Ersatz, keng Verschmotzung, héich Effizienz a reng;
3.Intelligent digitale Kontrollsystem, Allround Schutz;
4.High Präzisioun automatesch Energie Kontrollventil, stabil an zouverléisseg Operatioun;
5.Self-Diagnos Funktioun, intuitiv Affichage vum Alarmcode;
6.Real-Zäit Taupunkt Display, d'Qualitéit vum fäerdege Gas op ee Bléck;
7.Comply mat CE Normen.
TRV Serie gekillt Lofttrockner | Modell | TRV-15 Eng | TRV-20 | TRV-25 Eng | TRV-30 Eng | TRV-40 Eng | TRV-50 Eng | TRV-60 Eng | TRV-80 Eng | |
Max. Loftvolumen | m3/min | 17 | 23 | 27 | 33 | 42 | 55 | 65 | 85 | |
Stroumversuergung | 380V/50Hz | |||||||||
Input Muecht | KW | 3.8 | 4 | 4.9 | 5.8 | 6.3 | 9.7 | 11.3 | 13.6 | |
Air Päif Verbindung | RC2" | RC2-1/2" | DN80 | DN100 | DN125 | DN125 | ||||
Verdampfer Typ | Aluminiumlegierungsplack | |||||||||
Kältemëttel Modell | R407C | |||||||||
System Max. Drock erofgoen | 0,025 | |||||||||
Intelligent Kontroll a Schutz | ||||||||||
Display Interface | LED Taupunkt Display, LED Alarm Code Display, Operatioun Status Indikatioun | |||||||||
Intelligent Anti-Gefrierschutz | Konstant Drock Expansioun Ventil a Kompressor automatesch Start / Stop | |||||||||
Temperatur Kontroll | Automatesch Kontroll vun der Kondensatiounstemperatur / Taupunkttemperatur | |||||||||
Héich Volt Schutz | Temperatur Sensor | |||||||||
Niddereg Volt Schutz | Temperatursensor an induktiven intelligente Schutz | |||||||||
Energiespueren: | KG | 217 | 242 | 275 | 340 | 442 | 582 | 768 | 915 | |
Dimensioun | L | 1250 | 1350 | 1400 | 1625 | 1450 | 1630 | 1980 | 2280 | |
W | 850 | 900 | 950 | 1000 | 1100 | 1150 | 1650 | 1800 | ||
H | 1100 | 1160 | 1230 | 1480 | 1640 | 1760 | 1743 | 1743 |
1. Wat ass den Zweck vum Dryer am Frigo?
A: E Kältemëtteltrockner killt d'kompriméiert Loft of.
2.How laang wäert Dir d'Wueren arrangéieren?
A: Fir normal Spannungen kënne mir d'Wuer bannent 7-15 Deeg liwweren. Fir aner Stroum oder aner personaliséiert Maschinnen liwwere mir bannent 25-30 Deeg.
3. Akzeptéiert Är Firma ODM & OEM?
A: Jo, natierlech. Mir akzeptéieren voll ODM & OEM.
4. Wat sinn d'Komponente vum Kältelufttrockner?
A: En Loft-zu-Loft Wärmetauscher an e Loft-zu-Kältemittel Wärmetauscher.
5.What ass den Aarbechtsprinzip vum gekillte Lofttrockner?
A: Déi erausgekühlte Loft precoolt déi waarm erakommen Loft, condenséiert d'Feuchtigkeit, déi a flëssegt Waasser präsent ass, dat aus dem System drainéiert gëtt.